4045TF150
4.5L Generator Drive Engine
  • PowerTech™ M
  • Standby: 74 kW (99 hp) @ 1800 rpm
  • Prime: 67 kW (90 hp) @ 1800 rpm
Make an Enquiry on This Machine
Features
See how the 74 kW (99 hp) John Deere 4045TF150 generator drive diesel engine advances the standard of excellence with an electronically controlled or mechanical fuel system in OEM gen-set applications.
Expand All
Dynamically balanced crankshaft
  • Induction-hardened journals for long hours of reliable service
  • Robust design to drive machinery from the front of the crankshaft
  • Supported by five main bearings
Forged-steel connecting rods
  • 45-degree connecting rod/cap-joint design allows the use of large connecting rod bearings for increased durability
Replaceable wet-type cylinder liners
  • Provide excellent heat dissipation
  • Precision machined for long life
  • Rebuild to original specifications
Smooth operation
  • Smooth vibration with full length engine balancers
Easy to apply, easy to install
  • Front and rear engine mounting pads on the side of the block facilitates installation
  • Either-side service for filters and service points simplify installation and packaging
  • All connection points in common locations make it easy to install or package
Compact size
  • Short length is ideal for both skid and packaged installations
  • High mount or low mount turbocharger position to meet packaging requirements
World-class performance
  • Excellent fuel economy and low oil consumption
Fuel system controls
  • Proven and Reliable Mechanical Governor
  • 3-5% Droop Governing
  • 12V or 24V Electric Shutoff
Specifications
Expand All
General Engine Data
Model
4045TF150
Number of cylinders
4
Displacement-- L (cu in)
4.5 (275)
Bore and Stroke-- mm (in)
106 x 127 (4.17 x 5.00)
Compression Ratio
17.0:1
Engine Type
In-line, 4-Cycle
Aspiration
Turbocharged
Length - mm (in)
861 (33.9)
Width-- mm (in)
597 (23.5)
Height-- mm (in)
980 (38.6)
Weight, dry - kg (lb)
396 (873)
Performance Data Range
Hz (rpm)
50 ( 1500 )
Generator Efficiency %
88-92
Power Factor
0.8
Engine power - Prime kW
56
Engine power - Prime hp
75
Engine power - Standby kW
62
Engine power - Standby hp
83
Rated Fan Power - kW
2
Rated Fan Power - hp
2.7
Calculated generator set output - Prime kWe
47-50
Calculated generator set output - Prime kVA
59-62
Calculated generator set output - Standby kWe
53-55
Calculated generator set output - Standby kVA
66-69
Emissions Certifications
Non-Emissions Certified
John Deere Financial
We want to make owning and operating your equipment simple and affordable. 
We have a range of finance options to suit any customer.  Contact your local Emmetts branch, or visit these sites for more information and a free quote.