4045TF250
4.5L Generator Drive Engine
  • PowerTech™ M
  • Standby: 70-100 kW (94-134 hp)
     @1500-1800 rpm
  • Prime: 63-90 kW (84-121 hp)
    @ 1500-1800 rpm
  • Dual frequency available
Make an Enquiry on This Machine
Features
See how the 70-100 kW (94-134 hp) John Deere 4045TF250 generator drive diesel engine advances the standard of excellence with an electronically controlled or mechanical fuel system in OEM gen-set applications.
Expand All
Dynamically balanced crankshaft
  • Induction-hardened journals for long hours of reliable service
  • Robust design to drive machinery from the front of the crankshaft
  • Supported by five main bearings
Forged-steel connecting rods
  • 45-degree connecting rod/cap-joint design allows the use of large connecting rod bearings for increased durability
Replaceable wet-type cylinder liners
  • Provide excellent heat dissipation
  • Precision machined for long life
  • Rebuild to original specifications
Smooth operation
  • Smooth vibration with full length engine balancers
Easy to apply, easy to install
  • Front and rear engine mounting pads on the side of the block facilitates installation
  • Either-side service for filters and service points simplify installation and packaging
  • All connection points in common locations make it easy to install or package
Compact size
  • Short length is ideal for both skid and packaged installations
  • High mount or low mount turbocharger position to meet packaging requirements
World-class performance
  • Excellent fuel economy and low oil consumption
Fuel system controls
  • Proven and Reliable Mechanical Governor
  • 3-5% Droop Governing
  • 12V or 24V Electric Shutoff
Specifications
Expand All
General Engine Data
Model
4045TF250
Number of cylinders
4
Displacement-- L (cu in)
4.5 (275)
Bore and Stroke-- mm (in)
106 x 127 (4.17 x 5.00)
Compression Ratio
17.0:1
Engine Type
In-line, 4-Cycle
Aspiration
Turbocharged
Length - mm (in)
861 (33.9)
Width-- mm (in)
597 (23.5)
Height-- mm (in)
980 (38.6)
Weight, dry - kg (lb)
396 (873)
Performance Data Range
Hz (rpm)
50 ( 1500 )
Generator Efficiency %
88-92
Power Factor
0.8
Engine power - Prime kW
63
Engine power - Prime hp
84
Engine power - Standby kW
70
Engine power - Standby hp
94
Rated Fan Power - kW
2.5
Rated Fan Power - hp
3.4
Calculated generator set output - Prime kWe
53-56
Calculated generator set output - Prime kVA
66-70
Calculated generator set output - Standby kWe
59-62
Calculated generator set output - Standby kVA
74-78
Emissions Certifications
Non-Emissions Certified